O Series Replacement Coalescers for PecoFACET SuperFlex Housings
Parker Velcon O Series Coalescer Cartridges
Replacement Cartridges for Facet SuperFlex™ Housings
Superflex Replacement Cartridges - Data Sheet #VEL1867
O Series Coalescer and SO Separator Remove Water and Dirt from Diesel, Jet Fuel and Avgas
- Reduces free and emulsified water to less than 50 ppm in diesel, and less than 15 ppm in jet fuel/avgas.
- Used in place of Aquacon® cartridges for continuous removal of free water
- For use in the Facet SuperFlex housings in diesel and jet fuel/avgas service
DESCRIPTION
The Velcon coalescer and separator are installed together in the Facet SuperFlex housing to remove water and dirt from fuel. The fuel passes from the outside to the inside through the coalescer. Dirt is filtered out of the fuel and free/emulsified water in fuel is coalesced. The coalesced water droplets, which form on the inside of the coalescer, are repelled from going further down-stream by the separator. The water settles down to the sump where it is manually drained.
SPECIFICATIONS
- Maximum Operating Temperature is 160°F / 71°C
- Flow direction: outside to inside
- pH range: 5 to 9
- Coalescer Changeout at 15 psid
Replacement Cartridges for Facet SuperFlex™ Housings
Superflex Replacement Cartridges - Data Sheet #VEL1867
O Series Coalescer and SO Separator Remove Water and Dirt from Diesel, Jet Fuel and Avgas
- Reduces free and emulsified water to less than 50 ppm in diesel, and less than 15 ppm in jet fuel/avgas.
- Used in place of Aquacon® cartridges for continuous removal of free water
- For use in the Facet SuperFlex housings in diesel and jet fuel/avgas service
DESCRIPTION
The Velcon coalescer and separator are installed together in the Facet SuperFlex housing to remove water and dirt from fuel. The fuel passes from the outside to the inside through the coalescer. Dirt is filtered out of the fuel and free/emulsified water in fuel is coalesced. The coalesced water droplets, which form on the inside of the coalescer, are repelled from going further down-stream by the separator. The water settles down to the sump where it is manually drained.
SPECIFICATIONS
- Maximum Operating Temperature is 160°F / 71°C
- Flow direction: outside to inside
- pH range: 5 to 9
- Coalescer Changeout at 15 psid
Performance Characteristics | |
---|---|
Maximum Operating Temperature (F) | 160 |
Maximum Operating Temperature (C) | 71 |
Changeout Pressure Differential (PSI) | 15 |
Changeout Pressure Differential (Bar) | 1.03 |
Application | Aviation & Industrial |
Filter Type | Coalescer |
pH Range (Continuous Operation) | 5 -9 |
Brand | Velcon |